 Environmental Laboratory

We use our in-house facility to perform many of the more critical environmental tests in accordance with MIL-STD-810 requirements. This facility features a 10,000 force-pound, computer controlled LING Model 540A shaker which is capable of simulating the most severe military standard sinusoidal and random vibration profiles. This shaker can also replicate military standard shock spectra.

The laboratory is equipped with two temperature/altitude chambers capable of reproducing temperatures ranging from -100 degrees C to +200 degrees C and altitudes from sea level to 200,000 feet. A temperature/humidity chamber is available which can produce 0 to 95% relative humidity environments at temperatures to +125 degrees C. A salt fog chamber is available to replicate military standard test exposures. A unique tensile/shear/torque/compressive test machine can subject material coupons to structural loads to 20,000 pounds at temperatures between -100 degrees C to +315 degrees C.

There is a 70 cubic foot Agree ESS chamber with computerized monitoring capability. Its temperature limits are -75 degrees C and +80 degrees C. The shaker portion of this chamber can generate up to 5 Gs in the 20 through 60 Hz frequency range. A 14 cubic foot, fully automated, thermal chamber that performs to thermal limits of -80 v C to +180 degrees C is equipped with automated RF data acquisition capabilities linked to an HP 8720B Analyzer.

 

e-mail Sales
e-mail Webmaster
Updated11/7/02

Privacy Statement
 

L-3 Corporate Web SiteL-3 Contact Us