Supplier
Information
|
 |
| Large
Display Fault Indicator
Type CI 75 (Single Coil)
Type CID 75 (Dual Coil)
For Industrial Applications
|
 |
|
The CI series large display status indicator
feature a highly visible dual color internal flag. Available
in single and dual coil models. For industrial applications
demanding large displays while subjected to outdoor
elements, high ambient light areas and remote areas
requiring low power drain.
Covered
by U.S. and Foreign Patents. Patent No. 4,661,813
Cleared by DOD/OFOISR for public release under 00-S-1235
dated April 17, 2000.
|
 |
|
| |
Large 3/4" display |
| |
Visible in bright light or in
dimly lit area |
| |
No bulbs to replace |
| |
Low power usage
|
| |
No power needed when latched
in either position |
| |
Low cost |
| |
Strong magnetic memory |
|
| USE
FOR LARGE DISPLAY PANELS,
FAULT
WARNING SYSTEMS,
OUTDOOR APPLICATIONS OR IN OTHER BRIGHTLY LIT AREAS,
AND WHERE LOW POWER DRAIN IS REQUIRED.
OPERATION
When the indication coil is energized by a 50 millisecond
or longer pulse, color display flips 180 degrees and
latches to coil core. Display will remain magnetically
latched to the core in the position last pulsed. Even
if the signal is removed, indicator will "remember"
the signal instruction.
Reset to black is accomplished electrically
by pulsing a separate reset coil or by reversing polarity
in the single coil unit. The display then remains magnetically
latched to the core and remains black.
|
|
| Standard Coil
Voltage and Resistance Values |
|
Nominal
Voltage DC
|
Operating
Voltage
|
DC
Coil Resistance
in Ohms, ±10% @ 25°C
|
|
Min
|
Max
|
|
5
|
4.5
|
5.5
|
30*
|
|
6
|
5.5
|
6.5
|
41*
|
|
12
|
11.0
|
13.0
|
150*
|
|
20
|
18.0
|
22.0
|
460*
|
|
24
|
21.0
|
27.0
|
660*
|
|
28
|
25.0
|
31.0
|
875*
|
|
*Resistance
for coil for dual coil (CID 75) units
is approximately one-half the value listed
for single coil, all models.
|
| Nominal Operating
Pulse Power (at 25° C): 900 mw (CI 75);1.8
w (CID 75). Designed for pulse operation.
|
| Operating
Pulse Length: 50 ms min. |
| Reset Pulse
Length: 50 ms min. (Max. "On"
time 50%) |
| Dielectric
Withstanding Voltage: 100 VDC coil to
coil, for dual coil units. 500 VDC, terminals
to mounting panel. |
|
|
|
| Case:
Molded plastic, clear viewing lens. |
| Mounting:
Spring retainer, supplied with unit. |
| Weight:
30 grams |
| Display
Colors: Orange (set) and Black (reset). Other
colors or legends available. |
|
| |
| Operating
Temperature Range: -20°C to 85°C. |
| Operational
Life: 10,000 cycles minimum. |
|
|
|
When
ordering, show model number first, then coil voltage
desired, then the color combination desired. If this
is a special part, factory modification number will
be added at the end of the ordering number.
Example:
Single coil unit for 12 volt with
orange for set and black for reset would specify CI
75-12-0/Blk.
|
|
CI
75 - 12 - O
/ BLK - S
|
Basic
Model
Number
|
Coil
Voltage
|
Fault
or Set
Color
|
Reset
Color
|
Factory
Modification
Number if Special
|
|
CI
75
|
5
|
O
Orange
|
BLK
Black
|
S.+
ID No.
|
|
CID
75
|
6
|
O
Orange
|
BLK
Black
|
S.+
ID No.
|
| |
12 |
|
|
|
| |
20 |
|
|
|
| |
24 |
|
|
|
| |
28 |
|
|
|
|

NOTE: Dim. in ( ) are mm. Tolerances:Decimals:
± .010 (0,25) Fractions:± 1/64
| This
PDF contains a printable version of the hard copy
catalog page. |
 |
L-3-EDI
CI75-CIC75.pdf |
|
Note: Viewing and printing PDF files requires the
free Adobe Acrobat Reader program. You can download
Acrobat Reader from Adobe's
web site. |
|
|
|
|