DYNATIME®
Subminiature
Event Counters
|
 |
|
The Electrodynamics subminiature event
counters were designed to meet the most difficult requirements
of many military and aerospace applications. These rugged
counters meet or exceed an array of tough environmental
specifications including shock, vibration, temperature
and are packaged in a hermetically sealed miniature
enclosure. In addition, they have been approved to MIL-I-8974.
A variety of standard configurations are available.
We also welcome inquires for special requirements.
The ruggedized event counters are assembled
and filled with a dielectric lubricant that dampens
the effects of extreme vibration and thermal shock.
See Standard
Cases & Mounts and Pin
Headers information.
Cleared for Public Domain Release
by Directorate of Freedom of Information and Security
(DFOISR), dated April 17, 2000, reference number 00-S-1235
|
 |
|
| • |
Rugged Design |
| |
Hermetically Sealed |
| |
Qualified to MIL-I-8974 |
| |
Ruggedized Models Available
|
|
|
| Insulation
Resistance: MIL-STD-202, Method 302, Condition
B |
| Dielectric:
500 VRS @ 80,000 ft. |
|
|
Case:
Copper Nickel or Brass with flat painted finish.
E and F mounts are nickel-plated case with flat black
painted face.
Max.
case length: 1.094 in. |
| Flange:
Steel or Brass |
| Terminals:
Solder Hook |
Weight:
Standard: Will not exceed 1.0 ounces with C flange.
Ruggedized: Will not exceed 1.5 ounces with C flange. |
Numerals:
.035" wide, .078" high.
All digits are white on black. |
| |
| Operating Temperature
Range: -65 to +125°C |
| |
Standard Rating
|
Ruggedized Rating
|
| Count Rate: |
20 counts/second |
50 counts/second |
| Thermal Shock: |
MIL-STD-202, Method 107, Condition B
|
5000 hrs. -55 to +125°C |
| Shock: |
MIL-STD-202, Method 213, Condition I
|
MIL-STD-202, Method 213, Condition I
|
| Vibration: |
MIL-STD-202, Method 204, Condition B
|
10 - 90 Hz @ .07"DA,
90 - 400Hz @ 30g |
| Life: |
One million counts @ 25°C |
50 million counts @ 25°C |
ORDERING
INFORMATION
When ordering, show model number
first (B), then nominal voltage, case type, maximum counts
(4 or 5 digit), mount type and mount setback desired. If this
is a special part, customer's modification number will be
added at the end of the ordering number. This order chart
lists standard features. Other ratings and configurations
are also available.
Example: B-16-C8-CE-1
B
- 18 - C
- 8 - C
- E - 1
|
Model
Number
|
Voltage
Nominal
|
Case
Type
|
Maximum
Counts
|
Mount Type
|
Mount
Setback
|
Popular
Factory Codes
|
| B = Standard
|
16 = 28
VDC |
C = 4
Digit Square |
8 = 9999 |
A = no
mount |
A = Flush |
Code |
Description |
| L = Ruggedized |
Others
available
|
G = 5
Digit Rectangle
|
9 = 99999 |
Others available
see below
|
|
1 |
Rotated
90° Type C, C7, V, W Mount
|
| |
|
F = 6
Digit Rectangle
|
6 = 999999
|
|
|
14 |
4-40
Clinch Nuts, For Type C Mount |
| |
|
|
|
|
|
136 |
Tin plate front mount Type C (M7793/1 & /2), C7, V & W
|
Standard
Cases & Mounts






For
proper installation, please follow these instructions.
Standard
& Straight Pin Headers



NOTE:
Dim. in ( ) are mm. Tolerances: Decimals: ± .010 (0,25) Fractions:±
1/64
| This
PDF contains a printable version of the hard copy
catalog page. |
 |
L-3-EDI
Events Ctrs.pdf |
|
Note: Viewing and printing PDF files requires the
free Adobe Acrobat Reader program. You can download
Acrobat Reader from Adobe's
web site. |
|
|