Supplier
Information
|
 |
DYNATIME®
Digital Series
Solid
State, Panel Mount Hour Meters and Events Counters |
 |
DDS200 Series
The DDS200 solid-state Hour Meter and the DDS201 solid-state
Event Counter have been developed to meet the most difficult
requirements of military and aerospace applications.
In one panel mount package, the DDS200 series provides
a highly reliable means of monitoring critical system
usage, important for proper equipment maintenance.
The elapsed time and events
data can be read via the M7793/12 reader or through
the newly developed Palm™ PDA compatible interface
cable and software. With the Palm interface cable the
readings from multiple devices can be downloaded and
stored in an Excel™ compatible file that can be
synchronized with a laptop or desktop computer. This
allows the data to be used more effectively for analysis
of system usage. The interface cable is compatible with
all existing M7793/14 hour meters and event counters.
The time range for the DDS200
Hour Meter is 99999.99 hours. It has also been approved
to MIL-M-7793/14. The DDS201 Event Counter has been
successfully tested to the requirements of MIL-M-7793/14
and records counts when the unit receives power for
greater than 5 seconds. Power-on times of less than
4 seconds will not cause the counter to increment. The
count range is 9,999,999.
Cleared by DoD/OFOISR for public release
under reference number 06-S-1342 on April 20, 2006.
See
Dimensions
|

Palm™ PDA Interface Cable Assembly for extraction
of solid state Hour and Event Meter data. Downloads
using 16 pin Palm universal connector.
Supports Palm M500 Series,
Palm Zire 71, Tungsten T2, Tungsten T3 and others.
Requires software supplied
with cable assembly.
Cable length approximately 1 meter.
|
|
| • |
Monitors your system usage |
| |
Panel Mount Configuration |
| |
Non-Volatile Memory |
| |
Qualified to MIL-M-7793/14 |
| |
Download readings to Palm™
PDA |
|
| Electrical
Specifications |
| These meters meet
or exceed applicable requirements of MIL-M-7793
and M7793/14. Other ratings and configurations are
also available. |
|
Operating Voltage Range: 10-34
VDC and 20-30 VAC, 50-2400Hz. |
| Ripple
Voltage: Operates normally when subjected
to the ripple requirements of 5-2-2, 5-2-2-1 and
Figure 7 of MIL-STD-704A. |
| Output
Impedance: 100 k ??± 10 % |
| Logic
Zero: 0.0 to 0.2 V |
| Logic
One: 3.3 to 6.6 V |
| Power
Consumption: 50mW max. at 28VDC; 25mW max.
at 26VAC 400Hz. |
| Transient
Protection: No temporary or permanent degradation
in meter when subjected to input voltage and time
values shown in MIL-STD-704A, Figures 7 and 9, Curve
1 (600V and 80V transients, respectively). |
| Dielectric:
Withstands 600VRMS (room) and 350 VRMS (altitude).
applied between the power terminals and an external
ground. |
| Insulation
Resistance: MIL-STD-202, Method 302, Condition
B |
Accuracy: ± 0.1% over temperature/voltage
range |
| EMC:
MIL-STD-462, Methods CE03 and RE02 |
|
|
| Case
Dimensions: See below for detail dimensions. |
| Weight:
1 ounce max. |
| Hour
Meter—Time Range: 99999.99
hours |
| Event
Counter—Count Range: 9,999,999
counts |
| Meter
Output: Serial binary coded decimal format. |
| |
| Operating
Temperature Range: -65 to +125°C |
| Shock:
MIL-STD-202, Method 213, Condition I |
| Vibration:
MIL-STD-202, Method 204, Condition D |
| Salt
Spray: MIL-STD-202, Method 101, Condition B |
| Moisture
Resistance: MIL-STD-202, Method 106, Figure 106-1 |
| Altitude:
MIL-STD-202, Method 105, 0-80,000 feet |
Models
DDS200
and DDS201

| This PDF contains a printable version
of the hard copy catalog page. |
 |
L-3-EDI
DDS200-series.pdf |
|
Note: Viewing and printing PDF files requires the
free Adobe Acrobat Reader program. You can download
Acrobat Reader from Adobe's
web site. |
|
|
|
|